Protokół numer 005



Necessary material:

  • Device
  • K4 Cable
  • +12V power supply

Jak postępować:

  1. Remove the ECU from the original wiring of your vehicle;
  2. Connect the K4 cable to the Unit, using the configuration shown below;
  3. Connect the red and the black crocodile clips of the K4 cable to a +12V power supply;
  4. Connect the K4 cable to the device;
  5. Connect the device to the PC through a USB port;
  6. Run the device software from your PC.

Bosch ME7.3H4 (FIAT)

  PIN ECU   CABLE
     
  17   +12V
  18   +12V
  33   +12V
  49   +12V
  51   +12V
  2   K-Line
  Case   Ground




Connector without label:

  PIN ECU   CABLE
     
  20   Ground
  

Bosch ME7.3.1 (Alfa Romeo)

  PIN ECU   CABLE
     
  15   +12V
  16   +12V
  32   +12V
  47   +12V
  48   +12V
  53   K-Line
  20   Ground
  Case   Ground



Connector without label:

  PIN ECU   CABLE
     
  None   None

K4 cable uses the following wiring diagram:

  +12V     Biały, Zółty, Pomarańczowy, Czerwony, Niebieski    
  GND   Szary, Czarny
  K-Line   Green


If you don't use the K4 cable you have to connect through the universal cable 144300K201 using the following wiring diagram:

  Red     +12V    
  Black   Ground
  Yellow   K-line
  Green   CAN-L
  White   CAN-H


Ostrzeżenie:

Jeśli programowanie nie zostało zakończone, powtórz krok Zapisu bez wyłączania zapłonu i wybierz mniejszą prędkość.



`

Revision 2023-03-31 © Szymon Ławniczak | www.GeoningSystem.pl

Ostatni czas zmiany strony: 2023-03-31 05:18:45

Kontakt



E-mail: lawniczak.sz@gmail.com

Telefon: +48 667 089 498

WhatsApp: +48 667 089 498